kernel/Documentation/ABI/testing/sysfs-bus-iio-adc-stm32
sevki c9e1dba412 chore(ci): setup github actions and workflows
setup CI/CD for kernel development
- added CodeQL for code scanning
- every pr is built as an image and is available for
  30days on https://oklinux.dev
- tagged and released on github for now

Signed-off-by: sevki <s@sevki.io>
2024-03-15 21:46:24 +00:00

21 lines
643 B
Text

What: /sys/bus/iio/devices/triggerX/trigger_polarity
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
The STM32 ADC can be configured to use external trigger sources
(e.g. timers, pwm or exti gpio). Then, it can be tuned to start
conversions on external trigger by either:
- "rising-edge"
- "falling-edge"
- "both-edges".
Reading returns current trigger polarity.
Writing value before enabling conversions sets trigger polarity.
What: /sys/bus/iio/devices/triggerX/trigger_polarity_available
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
List all available trigger_polarity settings.